An
integral part of the Power Point operations. Our wealth of experience in
electrical inspection and testing is based on the need for companies to
conform with IEE 17th Edition - BS7671 (2008) and therefore, comply with
the Electricity at Work Regulations 1989.
DO YOU
KNOW IF YOUR ELECTRICAL INSTALLATION COMPLIES WITH CURRENT
LEGISLATION?
Certainly the regulations highlight the need to
maintain a regular program of inspection and testing of all electrical
systems. In addition it states that this must only be carried out by
'competent' persons.
We believe our inspection, testing and
maintenance service is more than just competent. In fact our comprehensive
programs are regarded as an essential service for many of our clients.
Whether providing site surveys, technical advice, producing fixed wiring
drawings or undertaking extensive testing programs, we are confident of
our ability to deliver the highest standards of quality and
service.
All our inspection and testing personnel are highly
experienced, certified electricians who hold a minimum of City &
Guilds 2381 - 17th Edition IEE Wiring Regulations and 2391 - Inspection,
Testing and Certification qualifications.
Our
comprehensive service includes:
 |
FREE ON-SITE
PRESENTATIONS Electricity
at Work Regulations 1989. Find out what you are responsible
for as a 'Duty Holder' i.e. Financial Director, Managing Director,
Health & Safety Manager, Electrical Engineer or Maintenance
Electrician and how to discharge your responsibilities. |
 |
FREE SITE
SURVEYS Enables us
to suggest a testing program to suit your production issues and
illustrates 'legal intent.' |
 |
ELECTRICAL NETWORK
DRAWINGS Following a
survey of your site, network drawings are produced containing
transformer details, bus-bar sections, cable sizes and cable type,
switchgear including isolators, control panels, distribution boards,
starters and motors, switchgear locations, ratings and fuse sizes.
The network is presented as a series of A1 size encapsulated
drawings and on CD-ROM in Autocad format. |
 |
CO-ORDINATED LABELING
SYSTEM Enables easy
identification with the relevant drawings and reports. |
 |
REPORTS AND FINAL CIRCUIT
DRAWINGS On
completion of the testing program a Periodic Report will be
issued. This is presented as a ring-bound copy, as well as on
CD-ROM. It contains 'Duty Holder' information and test methods
employed, characteristics of supply, a visual inspection checklist,
actual tests undertaken, characteristics of individual distribution
boards and test results and remedial
recommendations. |
|
|